Snagging Inspection (KD-01)
1-bedroom snagging
Apartment · 1 bedroom · 803 sq ft · Dubai · 08/10/2026
A compact apartment inspected before handover: every room, every test and a developer-ready snag list.
Sample reports
Three complete sample reports. Fictional homes, real format: the same IDs, grades and snag lists you receive.
Sample · Fictional property. Illustrations, not photographs.

Snagging Inspection (KD-01)
Apartment · 1 bedroom · 803 sq ft · Dubai · 08/10/2026
A compact apartment inspected before handover: every room, every test and a developer-ready snag list.
Snagging Inspection (KD-01)
Apartment · 2 bedrooms · 1,184 sq ft · Dubai · 13/10/2026
Our fullest sample: a 2-bedroom apartment with every room and system inspected, every test recorded and the developer submission summary.
De-snagging (KD-02)
Apartment · 2 bedrooms · 1,184 sq ft · Dubai · 24/11/2026
The same 2-bedroom home six weeks later: every earlier item marked Closed, Partly fixed or Open, with a close-out summary.
CriticalAn immediate risk to safety or of serious damage, such as exposed live parts, a socket with no earth, a loose balustrade or a fire door that will not close. We tell you the same day.
MajorA system or element that does not work as intended, lets water in, or will cause damage if left: hollow tiles, drainage that falls the wrong way, a leak, air-conditioning that does not cool.
MinorIt works, but it is not finished to standard and needs adjustment or a small repair: a misaligned door, a gap in the sealant, a loose fitting.
CosmeticAppearance only: paint touch-ups, scratches, stains and cleaning.
Tests that meet the expected result are marked Pass. At a re-inspection, each item is marked Closed, Partly fixed or Open. Grades are our professional opinion; the developer may classify items differently.
Explore a sample
Choose a sample, then filter by area or severity. It is the same data as the PDF report and the Excel snag list.
Sample
Snagging Inspection · 1-bedroom apartment · 803 sq ft · Dubai · 08/10/2026
Sample report · fictional property · illustrations, not photographs
Severity
Showing 42 of 42 findings
Sample · Fictional property. Illustrations, not photographs.
Door brushes the threshold
Entrance & hallway · Entrance door, bottom edge
Screw missing from the top hinge
Entrance & hallway · Entrance door, top hinge
Access panel sits below the ceiling
Entrance & hallway · Foyer ceiling, access panel
Scuffs and paint touch-ups at hand height
Entrance & hallway · Foyer walls, 0.9 to 1.4 m above the floor
Switch plate not flush
Entrance & hallway · Light switch beside the entrance door
Water stands in the door track
Living & dining · Balcony sliding door, outer track
Hairline crack in the ceiling
Living & dining · Living-room ceiling, parallel to the façade
Two hollow floor tiles
Living & dining · Living-room floor, centre of the room
Site dust inside the supply grille
Living & dining · Supply grille above the balcony door
Gap above the skirting
Living & dining · TV wall, skirting
Scratch on the glass
Living & dining · Fixed pane beside the balcony door
Mixer loose on the worktop
Kitchen · Kitchen sink mixer
One hob zone does not heat
Kitchen · Hob, rear right zone
Wall unit moves under hand pressure
Kitchen · Wall unit to the left of the hood
Chip in the worktop edge
Kitchen · Worktop front edge, left of the sink
Drawer stops short of closing
Kitchen · Top drawer below the hob
Sink trap joint weeps
Kitchen · Under the sink, trap
Protective film left on cabinet fronts
Kitchen · Wall units and tall unit
Wardrobe doors rub each other
Bedrooms · Bedroom wardrobe, left doors
Window handle stiff; locks on the second turn
Bedrooms · Bedroom window, handle
Hairline crack in the corner
Bedrooms · Bedroom, internal corner beside the bathroom wall
Stain in a floor tile
Bedrooms · Bedroom floor near the window
Veneer lifting on the door edge
Bedrooms · Bedroom door, lock edge
Thermostat reads 2 °C high
Bedrooms · Bedroom thermostat
Wavy paint line at the ceiling
Bedrooms · Bedroom, window wall at the ceiling line
Silicone stops short of the corner
Bathrooms · Bath, silicone to the wall tiles
Bath drains slowly
Bathrooms · Bath waste
Grout missing around the floor drain
Bathrooms · Bathroom floor drain
WC cistern keeps running
Bathrooms · WC cistern
Bidet spray drips when closed
Bathrooms · Bidet spray
No trim on the niche corner
Bathrooms · Tiled niche, external corner
Sealant smeared on the countertop
Bathrooms · Basin to countertop joint
Dark spotting and damp on the ceiling
Bathrooms · Bathroom ceiling above the bath
Cover strip missing from the base channel
Balcony · Balustrade base channel, left end
Hollow tile next to the drain
Balcony · Balcony floor, tile next to the drain
Paint splashes on the balcony wall
Balcony · Balcony wall beside the door
Water heater moves on its bracket
Laundry & store · Utility cupboard, water heater
Washing-machine valve turns only with a tool
Laundry & store · Washing-machine supply valve
Four breakers unlabelled
Electrical · Distribution board in the foyer
Condensation on the supply grille
HVAC · Bedroom supply grille
Dust cover left on the smoke detector
Fire & life safety · Living-room smoke detector
Sprinkler cover plate missing
Fire & life safety · Bedroom sprinkler
| Test | Reading | Guide | Result |
|---|---|---|---|
| Water: Kitchen sink | 3.6 bar, 8.8 L/min; hot water 50 °C at 31 s (max 57 °C); emptied in 16 s; drop at the trap joint | 1.0 to 5.5 bar; at least 50 °C within 60 s; no ponding 5 minutes after the test | Outside guide |
| Water: Bathroom basin | 3.5 bar, 6.2 L/min; hot water 50 °C at 27 s (max 58 °C); emptied in 10 s | 1.0 to 5.5 bar; at least 50 °C within 60 s; no ponding 5 minutes after the test | Pass |
| Water: Bath | 3.4 bar, 12.4 L/min; hot water 50 °C at 33 s (max 57 °C); 10 cm fill took 4 min; gurgles | 1.0 to 5.5 bar; at least 50 °C within 60 s; no ponding 5 minutes after the test | Outside guide |
| Water: Bidet spray | 3.5 bar; drips when closed | 1.0 to 5.5 bar; at least 50 °C within 60 s; no ponding 5 minutes after the test | Outside guide |
| Water: Washer valve | 3.6 bar; trapped drain point; dry | 1.0 to 5.5 bar; at least 50 °C within 60 s; no ponding 5 minutes after the test | Pass |
| Air-conditioning: Living | Supply 13.2 °C, return 24.4 °C, difference 11.2 °C, 51% RH | Supply 8 to 12 °C below return; 60% RH or less | Pass |
| Air-conditioning: Bedroom | Supply 11.2 °C, return 24.8 °C, difference 13.6 °C, 55% RH | Supply 8 to 12 °C below return; 60% RH or less | Outside guide |
| Moisture: Behind the bath (bedroom side) | 15 (dry reference 15) | Matches a dry reference of the same material | Pass |
| Moisture: Bathroom ceiling above the bath | 31 (dry reference 12) | Matches a dry reference of the same material | Outside guide |
| Moisture: Sink cabinet base | 13 (dry reference 13) | Matches a dry reference of the same material | Pass |
| Moisture: Living door threshold | 16 (dry reference 15) | Matches a dry reference of the same material | Pass |
| Moisture: Bedroom window sill | 14 (dry reference 14) | Matches a dry reference of the same material | Pass |
| Socket outlets, plug-in tester | 18 tested · 18 correct | Plug-in tester shows correct wiring: earth present, polarity correct | Pass |
| RCD test button at the board | Tripped and reset (with the developer’s permission) | Trips and resets | Pass |
| RCD, plug-in test at 30 mA | Tripped in 19 ms (recorded) | Trips (time recorded) | Pass |
| Light points and switching | 12 checked · 12 working | Every light works from its switch | Pass |
| Circuit schedule | 10 of 14 breakers named | Every breaker labelled | Outside guide |
| Leak check at the water meter | Meter moved while the WC cistern ran; still once it was isolated | No movement with every outlet closed for 10 minutes | Outside guide |
| Thermal sweep after 40 minutes of cooling | Cool patch on the bathroom ceiling; confirmed damp | No anomalies; any anomaly confirmed with a moisture meter | Outside guide |
| Tap test: every floor tile and wet-area wall tile | Three hollow tiles | No hollow sound on any part of a tile | Outside guide |
| Balcony water test, 10 litres | Water ran to the drain; none at the door | Water runs to the drain; no ponding 5 minutes after the test | Pass |
| Sliding-door track water test | Water stood in the outer track | Drains outwards; dry inside | Outside guide |
| Hob, oven and hood | One hob zone does not heat; oven and hood work | Every zone heats; oven heats; hood runs at every speed | Outside guide |
| Doors and windows, operated three times | 2 faults found | Operate freely and lock first time | Outside guide |
Snag ID
An area code and a number, so each item can be referenced in emails and on the handover certificate.
Location
The room and a precise position.
Photograph
Our reports include photographs of every item we record. The samples use illustrations instead.
KD-LIV-002
Living & dining · Living room, fixed window right of the balcony door
The glazing gasket has shrunk back 15 mm from the lower corner of the fixed pane.
Severity
MajorResponsible trade
Aluminium & glazing
Recommended action
Replace the gasket in one length and check the corner for draughts.
Severity
Critical, Major, Minor or Cosmetic.
Responsible trade
So the developer sends the right team.
Recommended action
What a proper fix should achieve, in plain words.
Snag ID
An area code and a number, so each item can be referenced in emails and on the handover certificate.
Location
The room and a precise position.
Photograph
Our reports include photographs of every item we record. The samples use illustrations instead.
Severity
Critical, Major, Minor or Cosmetic.
Responsible trade
So the developer sends the right team.
Recommended action
What a proper fix should achieve, in plain words.
Cover and report details: property, date, inspector, utilities status and weather
Summary: counts by severity and by area, and the items to fix first
How to read the report: grades, trades and snag IDs
A floor plan with every item pinned
Room-by-room findings, each with its photograph (illustrations in the samples)
Tests performed: water pressure, hot water, drainage, sockets and RCD, air-conditioning temperatures, moisture
An indicative area check against the SPA
A developer submission summary and handover-certificate guidance
Scope and limitations: what we inspected, what we tested and what we could not reach
Developers' repair teams work from spreadsheets, so you receive one. Each item is one row: Snag ID, Area, Location, Element, Description, Severity, Trade, Recommended action, Developer response, Status and Date closed. Filters and severity colours are built in, and we update the status after each re-inspection.
Snag list
SAMPLE| Snag ID | Area | Severity | Trade | Status |
|---|---|---|---|---|
| KD-LIV-002 | Living & dining | Major | Aluminium & glazing | Open |
| KD-KIT-004 | Kitchen | Minor | Tiling | Closed |
| KD-ENT-005 | Entrance & hallway | Cosmetic | Painting | Partly fixed |
KeyDay is new, and a client's report belongs to the client. So our samples use fictional properties, fictional data and line illustrations in place of photographs. The structure, grades, snag IDs, tests and wording are exactly what you receive, and your own report includes photographs of every item we record.
Send us your handover date and unit type. We reply with your fixed price in writing.